Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
i~umber Number

Page 1 of 11

Solicitation Contract

E48608-01-R-0001 F48608-01-D-0008 Page 12 of 58

B~D~G SCHEDULE FOR OPTION YEAR ONE ~ BUR & EPDM REFERENCE SPECIFICATIONS7510, 7530, 7559, 7620, 7631 CLIN# 1001 1001AA O01AB DESCRIPTION Section I EST. UNIT ESTIMATED AMOUNT 314.0( t8,199.7z 23,333.0( 13,333.0( 21,000.0( 4,383.75 5,260.5C 346.5~ 416.7: 111.0~ 333.0C : 3151.0C , 630.0~ 630.00 315!00 4!20 233i10 8,316i00 196,796i25 5,18100 6247500

QTY
Demolition RemoveAggregate Surfacing P, emoveMopped-On Roll Roofing & Underlayment: Slope 5/12 or less 1001AC RemoveBURS (5-ply max) & 2" Insulation (2" Mopped) 100lAD RemoveBallasted EPDM, Ballast, and All Undeflayment 001A~ Remove Adhered EPDM and All Underlayment 1001AF Remove Rigid Insulation (2" thick) Rigid Insulation (4" thick) [00lAG Remove [001AH Remove Underlayment / Vapor Barrier [001AJ Remove Metal Fascia / Flashing t001AK RemoveWoodNailers/Curbs [0o' ~L RemoveSealant .. ~ d R &R Curb Mount Equip ( 3'X3' Max- Unpowered) P~& R Curb Mo~t.Equip ( Yx3' Max'-P6~,£1ed) " 100lAP R & R Curb MountEquip (over 3'x3' -Powered) .001AQ Remove& Scrap Abandoned Mechanical Equipment/ Vents 001AR Remove& Scrap Sewer Vent/Pi ~e Flashing 001AS RemoveAbandonedConduit / Wiring 002 Install EPDM Membrane 002AA Adhered, Less Than 5 SQ Per Delivery Order 002AB Adhered, MoreThan 5 SQ Per Delivery Order 002AC Loose Laid, Ballasted w/Stone(10 lb/SF) 003 Install Insulation for EPDM Roofing 003AA ]~Install Insulation, Minr Value>= 12 004 Install Roll Roofmg 004AA ~Install Roll Roofing System 005 Install 4-Ply BURS with Insulation & Gravel 005AA ess Than 5 SQper Delivery Order/20 yr Warranty 005AB ore Than 5 SQ per Delivery Order/20 yr Warranty 00SAC ore Than 5 SQ per Delivery Order/20 yr Warranty (Base 2O0 23,333i SF 23,333 13,333 600 167 167 22 1,667 111 333
' '2"

PRICE

/

1:57 .78

2 2 111 33 833 33 833 3 4 4 5

1.00 1.00 35.00 SQ SQ 26.25 31.5C SQ 15.75 se LF .25 SF 1.0C LF 1.0O ,.1.5~50 :~." ' :EA~: 2! 21.0:00 ' :210.00 EA 157.50 EA LF 2.10 2.10 252.00 236.25 157.00 75.00

SF SF

SQ se

L

SQ SQ

420.0C 315.0C 275.00

1,680,0C 1,260.0C 1,375.0C

x 00

~

Mechanically Fasten Plywood Deck echanically Fasten 5/8" Plywood Deck, as Substrate, sing Manufacturer's Suggested Fastening System
Revised per Amendment 0001, dated 12 March 2001

157.50

472.51

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
~umber Number

Page 2 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 Page 13 of 58

1007 Curb Extension 1007AA ]]2" x 6" Curb Extension w/Standard Ducting 1008 1/2" Plywood (CDX)Used as Roof Substrate 1008AA ~1/2" Plywood(CDX)Mechanically-Fastened up to 12" ]_[Wide 1009 Install Drip Edge 1009AA ]~Install Drip Edge, Galv., 24 Ga. 1010 Install G.I. Flashing I010A.A 5" Drip Edge& Eave Flashing, 26 Ga. 1010AB 8" Drip Edge& Eave Flashing, 26 Ga. 1010AC 12" Flashing, 26 Ga. 1010AD Valley Flashing, 24" W, 26 Ga., Standard "v" Shape 1010AE Step Flashing 12" x 8", 26 Ga. 1010A~ Wall MountedReglet 26Ga.,Mechanically Fastened, 6" Face I010AG Counter Flashing 12 Wide 26 Ga. 1010AH . GrovelStop, 6" Face, 24 Ga. 1010AJ Gravel Stop, 4" on Concrete Decks 1010AK Gravel Stop, 4", Include 2 x 6 Nailers 1010At Ventilator, Remove Install, All Accessories & 1¢ Remove,.Rebend & Replace AluminumCoping. ' '~ R~plaeeDamake-d:.Wood Sh~atlli~ :hind Deeking~ 1/2. -Plywood ~. " -" l(ll lAB. 5/8" Pl.ywood 1011AC 3/4" Plywood 1011AD 1 1/2" T&G Joint Plank & Paint (exterior) V t011AE 1 1/2" T&G Joint Plank & Stain interior) V [011AF Wood Nailer - 6" & up Nora Width I011AG WoodNailer - 4" NomWidth 1011AH WoodFascia 1012 Gutter & Downspouts [012AA RemoveDownspout & Cap Gutter RemoveGutter/Downspout [012AC Gutter, "K", 5", 26 Ga. [012AD PrefmishedGutter, 24 Ga., max30" Stretchout 012AE Downspout,2x3", 26 Ga. .012AF Downspout, 3x4", 26 Gm .012AG iDownspout,Round, Corrugated, 4" 012AH Prefmished Downspout,26 Ga., max30" Stretchont 012AJ Gutter Lining, Brush Applied RubberSealant 012AK Gutter Lining, EPDM, rail 60 Gutter Screen Mesh Gutter, 1/2 Round,5", 26 Oa.
Revised p.er .Amendment 0001, dated 12 March 2001

- 2.82 1.813 2.24 1.83 3.39 2.42 1.6( 1.83 1.2] .87 1.19 105.00 ,.t:00 ', ~1.43 i. 1.54 1.65 7.35i 7.35 2.75 2.1(3 3.15 5.25 1.05 3.15 6.30 3.15 3.40 3.70 3.15 2.10 5.25 2.10 5.25

333 1,667 300 1,100 117 1,667 2O0 2O0 8O0 5 3,333

LF LF LF LF LF LF LF LF LF EA LF : SF: ~ SF: SF LF LF LF LF EA LF LF LF LF LF LF LF LF LF LF LF

745.92 3,050.61 1,01Z.013 2;662.013 194.22 3,050~61 24200 17400 ." 95200 ii:.. 52500 !. .3,33300 95381 51282 5,49945 12495 12495 45925 1,400713 34965 3675 583.80 349.65 422.1( 176At0 227.80 12Z10 211.05 350.70 876.70 350.70 57.75

3,333 17 17 167 667 111 7 556 111 67 56 67 33 67 167 167 167 tt

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number Contract

Page 3 of 11

Solicitation

F48608-01-R-0001 F4~608-01-D-XXXX Page 14 of 58

I013 WSA Access Delays I013AA ~Delays ~014 ~tection System Remove Integrated System Air Terminals and Conductors 1014A.A 014AB WorkAroundConcealed Light~nSmg Protection System, Add lNs Cost to Roof Installation Cost per SQ )14AC Restore Integrated SystemAir Terminals and Conductors 014AD Electrically Test Restored Sys~ations 015 Miscellaneous 015AA Crane Rental 015AB Factory FormedRubber Flashing Boot (up to 6" Dia) 015AC Replace Vent Rain Hood(to 8" Dia Vent) Ol5AD Replace Vent Rain Hood(to 16" Dia Vent) 915AE Steel plate -3/16" (Over Abandoned Penetrations) 315AF Reroute Conduit/Wiring 315AG Painting 316 LowSlope Roof Accessories 316AA Concrete Paver Blocks, 2' x 2' Square x Approx.2" Deep, Minimum Weight 40 lb. Each ?" q Metal Roof Drain Domes ). .J Metal RoofDrain Inserts )16A.D Metal Roof Drain Rings )16AE Metal Roof Drain Bolts

96.00 500.00 10.50 ~00.00 2000.00 200.00 105.00 105.00 130.00 10.25 3.15 1.05 4.213 "5000.( 3,496.50 6500;00 2000i00 1,000i00 1,365i00 315i00 39000 51250 15750 315@ 210!01 106.01 106.00 106.00 63.00 427~997,88

333 13 1

se
EA EA HR EA EA EA SF LF SF EA

I5
13 3 3 50 50 300 50

2 EA 53.00 2 EA 53:00 2 EA 53.00 6 EA 10.50 ESTIMATED TOTAL

M~TAL ROOFING REFERENCE SPEC]I~ICATIONS7530, 7611, 7620, 7631 CLIN # DESCRIPTION- Section EST. UNIT UNIT PRICE 16.0C .33 1.05 1.05 160.00 210.00 210.00 160.00 2.10 2.10 ESTIMATED AMOUNT 352.0( 550.11 116.55 349.65 320.013 630.00 630.00 320.0( 4.20 233.10

QTY
017AA RemoveUnderlayment / Vapor Barrier 017AB Remove Metal Fascia / Flashing 017AC Remove WoodNailers/Curbs 017AD RemoveSealant 017AE R & R Curb MountEquip ( 3'x3' Max- Unpowered) 017AF R & R Curb Mount Equip ( Yx3' Max- Powered) 017AG R & R Curb Mount Equip (over 3'x3'- Powered) 017AH Remove& Scrap Abandoned Mechanical Equipment/Vents Remove& Scrap Sewer Vent/Pi ~e Flashing RemoveAbandoned Conduit / Wiring .
Revised per Amendment 0004, dated 28 JItne 2001

22 1,667 111 333 2 3 3 2 111

SQ LF SF LF EA EA EA EA EA LF

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 4 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 Page 15 of 58

Mechanically Fasten Pl....~~ood Deck 1018AA M~-anically Fasten 5/8" PlywoodDeck, as Substrate, ~ested Fastening System 1/2" Plywood(CDX)Used as Roof Substrate 1019 ~019A~A, 1/2" Plywood(CDX)Mechanically Fastened up-t~ 12" Wide 1020 Re lap_~__DamagedWoodSheathing and Deckin_~__ 1020AA 1/2" Plywood. 1020AB 5/8" Plywood 333 SF 1020AC 3/4" Plywood 3,333 SF 1020AD 1 1/2" T&G Joint Plank & Paint (exterior) V 17 LF 1020AE 1 I/2" T&G Joint Plank & Stain (interior) V 17 LF 1020AF WoodNailer - 6" & up Nora Width 167 LF 1020AG WoodNailer - 4" NomWidth 667 LF 1020AH WoodFascia 111 LF 1021 Gutter & Downspouts 1021AA RemoveDownspout & Cap Gutter 7 EA 102lAB RemoveGutter/Downspout 556 LF 1021AC Gutter, "K", 5", 26 Ga. 111 LF 102lADPrefinished Gutter, 24 Ga., Max30" Stretchout 67 LF 1021AE Downspout, 2x3 , 26 Ga. 56. .LF 10" D0._wnspout, 3x4", 2~. Ga.. ! ~67:: LE " . ....... 10. Dbwnspout, Round;- Corrugated, 4" .... .: : . ~ ' ~ :33: ';~F' 1021AH. Pr~fiulshed Downspdut, Ga., max30". Stretchout .' 26 ; '67. i021AJ Gutter Lin~g, Brush:Applied Rgbber Sealant '167 LF 1021AK Gutter Lining, EPDM, rail 60 167 LF 1021AL Gutter Screen Mesh 167 LF 1021AM Gutter, 1/2 Round,5", 26 Ga. 11 LF 1022 Standing_SeamRoofmg._ 1022AA Remove Standing SeamRoofing, Drip Edge, & 3,000 SF Underlayment 1022AB Roofing Panels, 24 Ga. 3,000 SF 1022AC Prefinished Drip Edge, 24 Oa., 233 LF I022AD Prefinished Reglet, 24 GA 100 LF [022AE Metal Z-Purlin and All Clips, Fasteners, and Accessories 333 LF Prefinished Ridge Cap 167 LF [022AG Prefinished Valley Flashing 167 LF [ 022AH Prefinished Metal Fascia 167 LF [022AJ Apply Acrylic Membrane Waterproofing System 3,333 SF [ 022AK Batt Insulation 333 SF [ 022AJ~ Quick Fix, Place Self TappingScrhws, Twoper Sub-Purlin 333 LF ~er Panel WSA Aeeess Delays Delays 50 CR

150.00

450.

~

10.0

- 1.45 1.55 1.65 7.35 7.35 2.60 2.10i 3.15i 5.25 1.05 3.15 6.30 : 3.15 + :. 3A0 .... " .3:75:.: : :;

967.15 516.15 5,49~.45 124.95 124~5 434.2C 1;400.7C 349.65 36.75 583!.8C 349.65 422.10 1,76!.40 , 227.80 19"":

5.25 1.05 5.25 .60 3.00 2.10 2.10 7.50 2.10 2.10 2.1e 1.0C 1.3~ 1.05

876L75 17535 5775 1,80000 9,000 00 48930 21000 2,49750 3507C 3507~ 3507£ 3330C 4329C 349.65

7.00

350.:00

Revised

per

Amendment

0001,

dated

12

March

2001

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 5 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 Page 16 of 58

Li htnin Protection System [ 024 Integrated System Air Terminals and Conductors [024AA Remove 500.00 1024AB WorkAround Concealed Lightning Protection System, Add 333 SQ 10.50 This Cost to RoofInstallation Cost per SQ ¯ :.., _, 1024AC Restore Integrated SystemAir Terminals and Conductors 13 EA 500.00i 1024AD Electrically Test Restored Syst~ecifications 1 EA ' 2000.0C Miscellaneous .025A.A Standing Seam Seaming Machine 1 MO 880.00 1025AB iCrane Rental 5 HR. 80.00 1025AC Tighten Metal Roof Fasteners 900 EA 1.05 1025AD Replace Metal Roof Fasteners 200 ~A 1.05 1025AE Replace Vent Rain Hood(to 8" Dia Vent) 3 EA 105.00 1025AF Replace Vent Raha Hood(to 16" Dia Vent) 3 EA 130.00 1025AG Steel plate -3/16" (Over Abandoned Penetrations) 33 SF 4.15 1025AH Reroute Conduit/Wiring 33 LF 3.15 t025AJ Painting 200 SF 1.05 ESTIMATED TOTAL SHINGLE & CLAY TILE REFERENCE SPEC/FICATIONS 731t~ 7320~ 7530, 7620~ 7631 llI. '. cLI~# D~:~CRiP~mN-.-See~o~(' 026 026AA 026AB 026AC ..... : Demolitioh 1 Shingle Layer w/1 layer felt: slope 5/12 to 8/12 ~TY 509 60 1 1 1 1 2,791 355 32 I PlaICE

5000.00 3,496.50 6500.00 2000.00 880.00 400.00 945.00 210.00 315.00 390.00 136.95 103.95 210.00 57266.51

(1 Story)
2 Shingle Layers w/1 layer felt: Slope 5/12 to 8/12 (1 Story) 3 Shingle Layers w/1 layer felt: Slope 5/12 to 8/12

19851.00

se SQ SQ se SQ SQ se se

48.47 52.15 48.02 52.15 56.18 45.00 52.15 56.18

2,908!.20 5Z.15 48!02 52i15 5618 12559500 18,51325 1,797i76

(1 Story)
Slope >8/12 to 12/12 Slope >8/12 to 12/12 Slope >8/12 to 12/12 Slope 5/12 to 8/12 Slope 5/12 to 8/12 Slope 5/12 to 8/12

1 Shingle Layer w/1 layer felt: 026AD (1 Story) 2 Shingle Layersw/1 layer felt: 026AE (1 Story) 3 Shingle Layersw/1 layer felt: 026AF [1 Story) 1 Skingte Layerw/1 layer felt: 026AG :~>1Story) 2 Shingle Layersw/1 layer felt: 026AH (>1Story) 3 Shingle Layersw/1 layer felt: (>1 Story)

Revised

per

Amendment

0001,

dated

12

March

2001

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 6 of 11

Solicitation Contract

E48608-01-R-0001 F48608-01-D-0008 Page 17 of 58

1 Shingle Layer w/1 layer felt: Slope >8/12 to 12/12 1026AK (>1 Stow) 2 Shingle Layers w/1 layer felt: Slope >8/12 to 12/12 1026AL (>1 Stow) " 3 Shingle Layers w/1 layer felt: Slope >8/12 to 12/12 1026AM (>1 Stow) 1026AN 1 Layer Felt 1026AP 2 Layers Felt Remove Clay Tile Roofing & Underlayment Including 1026AQ Nailing Strips if Present Underlayment/ Vapor barrier 1026AR Remove 1026AS RemoveWoodNailers/Curbs 1026AT RemoveSealant Remove& Scrap Abandoned Mechanical Equipment/ 1026AU Vents Flashing 1026AV Remove& Scrap Sewer Vent/ 1026AW RemoveAbandoned Conduit / Wiring ~027 Install New Felt &Shingles 1 Layer 30 lb Felt & WindResistant T-LockShingle : 1027AA Slope 5/12 to 8/12 (1 stow) , 1 Layer 30 lb Felt & WindResistant T-Lo.ck!Sl~gle-;., -.. 10. ~ Slope >8/12 to 12/12 (1 Story) ...... ~. ba~ei ~0~ .lb.~@:&3Yind Resistant T:LockShingldi: ; 1027AG: Slope 5/12 to,8A12(>1 stow) 1 Layer 30 lb Felt & WindResistant T-LockShingle : 1027AD ISlope >8/12 to 12/12 (>1 Story) 11 Layer 30 lb Felt & 100 mphThree Tab WindWarranty 1027AE Shingle : Slope 5/12 to 8/12 (1 story) 1 Layer 30 lb Felt & 100 mphThree Tab WindWarranty 1027AF Shingle : Slope >8/12 to 12/12 (1 story) 1 Layer 30 lb Felt & 100 mphThree Tab WindWarranty 1027AG Shingle : Slope 5/12 to 8/12 (>1 stow) 1 Layer 30 lb Felt & 100 mphThree Tab WindWarranty 1027AH Shingl_~e: Slope >8/12 to 12/12 (>1 stow) 1028 Install Felt 1028AA Install 1 Layer30 lb Felt 1028AB [[Install 30 lb Felt Ice Dam 1029 HandSeal Shingles 1029AA ]]Hand Seal Shingles 1030 Storm.Nail 1030~-~Extra Storm Nail, Each Tab Twice 0VIin. 100 LF) Install NewFelt & Wood Eave t 0' Strips for Clay Tile Roofm/~ ~5 __ ,A--~Install New Felt & Wood Eave Strips for Clay Ti!e Roofing
Revised ~er Amendment 0001, dated 12 March 2001

32 9 :9

SQ se SQ

52.15 56.18 62.54 .2C .35 80.0C 1.05 3.15 1.05 160.00 2.10 2.10 95.00

1,688.8( 05.6x 562.8~ 2,666.6C 1,750.0C 8000.0C 23.1C 349.65 ~49.65 320.0C &2( 233.10 045.00

13,333 SF 5,000 SF 100 SQ 22 111 333 2 2 Ill 11 .1
~.

~se
SF LF EA EA LF

S:~ .... 110.00 :. !:1:'.~ ~r~t
SQ: 2]. ', :: ~zQ~O0 ~ .'''

- 1~o~oo
~2
'.'

i:
r :

¯ : ,

360i00 t25L50 4464000 90~00

1 558 t 3,185 42

SQ SQ SQ SQ SQ

125.00 80.00 90.00 83.00 100.00

26435500 4,20000

333 5,000 60 2,000

LF

35.00 1.20 1.00 .25

11,65500 6,000i00 60i00 500!00

100

70000

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 7 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 ~ Page 18 of 58

Install Clay Tile Roofing i-0_ 1032AAField Tile 630. 7 1032AB Field Tile (ReplacementOnly) EA 630.00 4,410.0( I032AC Ridge Tile 3 EA 630.00 1,890.0( ' Ridge End 1032AD EA 630.00 630.0( i032AE End Band 3 EA 630.00 1,890.0( i032AF Gable Rake 3 EA 630.00 1,890.0( 1032AG Hip Roll 3 EA 630.00 1,890.0( 1032A-~ I lHipStarter 2 EA 630.00 1,260.0C 1032AJ I II-Iip Terminal 1 EA 630.0C 630.0! 1033 Removeand Refasten Clay Tile Roofing Remove and Refasten Clay Tile Roofing: One Layer 301b 105.0C 525.0C 1033AA Felt, Scaffolding, and Fasteners 1034 Mechanieaily Fasten Plywood Deck Mechanically Fasten 5/8" PlywoodDeck, as Subslrate, 105.0C 450.0C I034AA Using Manufacturer's Suggested Fastening__System 1035 1/2" Plywood(CDX)Used as Roof Substrate 1/2" Plywood(CDX)Mechanically Fastened up to 12" 1.6G 32.0C 1035AA Wide 1036 Install Drip Edge 1036AA ~[Install Drip Edge, Galv., 24 Ga. . ~ ... 450 2.75 1,2.3Z.5C ic Install G.I. F~ashing" ~ .. ..... " ' ..... ~-. ?:~::2.61 ¯ - .... !5,220.00 i-0~,....~k l lDrjp Edge EaveF~ashing & 26Ga: ...... i ' P.:,000 I037AB:]Valley Flashing, 24":W,'26 Ga., Standard "V" Shape , .... 3,3.9 [ !300),' ¯ ! ,' 1;0!7.00 1037AC-- Roll(Screw F~tened) 2 1/2"-Dia., 26 Ga. ..... '--- 22200 ': : .- " ~.15 ' .... 3a0.00 I Image 1037ADStep Flashing 12" x 8', 26 G~ LF 2.42 2,662.00 ,, 1,100 LF 1 t7 1.66 19422 I IWall Mounted Reglet. 26 Ga., MechanicallyFastened, 6 1037AE]_[Face 1038 Install 16 oz cow_per 1038AA iValleyFlashing, 24"W 13.52 8112( 1038AB Comer Flashing 9 LF 13.52 121i68 103 SAC Cricket 3 EA 520 1,560i00 1038AD Surface MountFlashing 2O LF 13.52 27040 I038AE ~ Flashing, 15 LF 13.52 202i80 1039 Re la~_~_~Damaged Wood Sheathing and Decking 1039AA 1/2" Plywood 667 1.43 953i81 1039AB 5/8" Plywood 333 SF 1.54 512i82 1039AC 3/4" Plywood 3,333 SF 1.65 5,499~45 1039AD 1 112" T&G Joint Plank & Paint (exterior) 17 LF 7.35 12495 V 1039AE 1 1/2" T&G Joint Plank & Stain (interior) 17 LF 7.35 124i95 V I039AF WoodNailer - 6" & up NomWidth 167 LF 2.75 459i25 1039AG Wood Nailer - 4" Nora Width 667 LF 2.10 1,400 70 i0" WoodFascia 111 LF 3.15 349i65

I

Revised

~er

~endment

0001,

dated

12

March

2001

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 8 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 Page 19 of 58

1040AA 040AB L040AC 040AD [040AE 040AF [040AG [040AH 040A~ L040AK [040AL [040AM t041 ~41AA [041AB [041AC [04lAD )042 z" t0 ~ A [ 04zAC t042AD t042AE [042AF

Gutter & Downspouts 5.25 RemoveDownspout & Cap Gutter 556 LF 1.05 58~.8C ~.emove Gutter/Downspout 349.65 111 LF 3.15 Gutter, "K", 5", 26 Ga. 67 -LF 6.30 .422.1C Prefinished Gutter, 24 Ga., max30" Stretchout 56 LF 3.15 176.4¢ Downspout,2x3", 26 Ga. 67 LF 3.40 227.8~ Downspout,3x4", 26 Ga. 122.1~ 33 LF 3.70 Downspout,K6und, Corrugated, 4" 211i.05 67 LF 3.15 Prefmished Downspout,26 Ga., max30" Stretchout 167 LF 2.10 350.7~ Gutter Lining, Brush AppliEdRubberSealant 167 LF 5.25 876.75 Gutter Lining, EPDM, rail 60 167 LF 1.10 183.7C Gutter Screen Mesh 11 LF 5.25 57.75 Gutter, 1/2 Rotmd,5", 26 Ga. ~tection System Remove Integrated System Air Terminals and Conductors 10 EA 500.00 5000.0~ SQ 10.50 3,496.5~ WorkAround Concealed Lightning Protection System, Add 333 This Cost to RoofInstallation Cost per SQ 13 EA 500.00 6500.0C Restore Integrated SystemAir Terminals madConductors 2000.0~ Electrically TesfRestored-Sstem er S ecifications EA 2000.00 Miscellaneous 5 I-lR 200.00 Crane Rental 13 EA 105.00 1,3651.0~ Factory FormedRubber Flashing Boot (up to 6" Dia) 33 SF .5.25 173!.25 Steel Plate -3/16" (Over Abandoned Penetrations) 33 LF 3.15 103!.95 Reroute Conduit/Wiring 20O SF 1.05 210.0C Painting 1 YB Not Separately Contract Data Requirement List (See Section J, Exhibits Priced andB) 582403.92 ESTIMATED TOTAL 42799%88 57266.51 582403.92

TOTAL ESTIMATED DOLLAR AMOUNT SECTIONI (CLINS 1001 THROUGH FOR 1016AE) TOTAL ESTIMATED DOLLAR AMOUNT SECTIONH (CLINS 1017 THROUGH FOR 1025AJ) TOTAL ES'IIMATEDDOLLAR AMOUNT SECTIONl~ (CLINS 1026 THROUGH FOR 1042AF)

OTAL ESTI2VIATED DOLLAR AMOUNT 1~t OPTION FOR PERIOD (CLI2NS 1001 THROUGH 1042AF:) 1,067668.31

Revised

per

Amendment

0001,

dated

12

March

2001

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 9 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 Page 20 of 58

BIDDING SCHEDULEFOR OPTION YEAR TWO(2) ~ ~.. BUR & EPDM :. REFERENCE SPECIFICATIONS 7510, 7530, 7559, 7620, 7,631 CLIN # DESCRIPTION Section 2001 2001AA 200lAB

Demolition RemoveAggregate Surfacing RemoveMopped-On Roll Roofing & Underlayment : Slope 5/12 or less 2001AC RemoveBURS (5-ply max) & 2" Insulation (2" Mopped) ~ 200lAD Remove Ballasted EPDM, Ballast, madAll Underlayment 2001AE RemoveAdhered EPDM and All Underlayment ).0OLAF. Remove Rigid Insulation (2" thick) ).00lAG Remove Rigid Insulation (4" thick) 2001AH [~emoveUnderlayment/ Vapor Barrier 2001AJ Remove Metal Fascia / Flashing 200" "K Remove WoodNail.ers/Curbs ~ ~ ~emove Sealint " :~ " ' P,.: ~:_RCurbMo~Jat Equip(3'x3' Max Unpo.were.d) '. ._ ~.O01AN R. & R Curb MOunt Equip ( 3'x3' Max- Powered) ~.O01AF R & R Curb MountEquip (over 3'x3' - Powered) I001AQ Remove& Scrap Abandoned Mechanical Equipment/ Vents ~.O01AR Remove& Scrap Sewer Vent/Pipe Flashing ~.O01AS RemoveAbandoned Conduit / Wiring ~.002 Install EPDM Membrane Z002AA Adhered, Less Than 5 Per Delivery Order SQ ~.002AB Adhered, More Than 5 SQ Per Delivery Order !002AC Loose Laid, Ballasted w/Stone (10 lb/SF) ~.003 Install Insulation for EPDM Roofing ~.003AA ]~Install Insulation, Minr Value>= 12 ~.004 Install Roll Roofing ~stall Roll Roofing S.___.~ystem ~.005 Install 4-Ply BURS.with Insulation & Gravel ~.005AA Less Than 5 SQ per Delivery Order/20 yr Warranty .~005AB More Than 5 SQ per DeliveryOrder/20 yr Warranty ~005AC Mere Than 5 SQ per Delivery Order/20 yr Warranty (Base Housing)

'1

I

EST. UNIT

QTY

UNIT ESTIMATED PRICE AMOUNT 1.59 .80 31800 18,66640

I/ 200
23,333 23,333 13,333 i600 167 i 167

SF SF SF SF SQ SQ SQ

22
1,667 111

SQ
LF SF

3 2 2 111 33 833 33 833 3 4 4 5 S(

EA EA EA LF

1.01 2356633 1.06 1413298 37.10 2226000 26.50 442550 31.80 531060 15.90 34980 .26 45342 1.06 ' ,. ¯ .lf766 ~ '!.06 ':~ 35298 ~159.00 .; ¯ , 31800 ': = 216" 648i00 216.00 648i00 159.00 31800 202.16 2.16 40431

159.0C 62475.

SQ I 333.90 SQ I 291.50

1780.~80 1335.!60 145750

Revised

p~r

Amendment

0001,

dated

12

March

2001

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005
Number Number

Page 10 of 11

Solicitation Contract

F48608-01-R-0001 F48608-01-D-0008 Page 21 of 58

200b Mechanically Fasten Plywood Deck 2006AA HMechanicallyFasten 5/8" PlywoodDeck, as Substrate, 500.85 _JJUsing Manufacturer's ~ Fastening System 2007 Curb Extension 2007AA J]2" x 6" Curb Extension w/Standard Ducting___ 5.3C 318 1/2" Plywood(CDX)Used as Roof Substrate 2008 2008AA 1/2" Plywood(CDX)Mechanically Fastened up to 12" 40.02 200.4C Wide ):009 Install Drip Edge 2009AA ~Install Drip Edge, Galv., 24 Ga. 2.99 1345 2010 Install G.I. Flashing 2010AA 5" Drip Edge& Eave Flashing, 26 Ga. 1.91 3183 2010AB 8" Drip Edge & Eave Flashing, 26 Ga. 333 LF 2.37 .,789;.21 2010AC 12" Flashing, 26 Ga. 1,667 LF 1.94 3233.98 2010AD Valley Flashing, 24" W, 26 Ga., Standard "v" Shape 300 LF 3.59 1077.00 ~OtOAE Step Flashing 12" x 8", 26 Ga. 1,100 LF 2.57 282700 ~.010AF Wall MountedReglet. 26 Ga., Mechanically Fastened, 6" 117 LF 1.76 20592 Face ~.010AG Counter Flashing 12" Wide26 Ga. 1,667 LF 1.94 . i 323398 200 Gravel.Stop,6.'7 Face, 24 Ga. LF 1.28 ~ 2, 25600 LFGravel Stop, 4" on.Concrete Decks 200 :~.:; -...92 ¯ t ":1'8400 GravelStop, 4", Include~2 x6 NaiIer~: ~. ':: :.1.26 " 1008100 V~nffiit6r, Refiaove &I~stall, All:Ac6~ori~s........... " EA..: ~ :.i11.00 ." 55500: ~emoi)~, Rebend & Re~lace A)~ Cbpin~ "'-: ..... " 3;333. ¯ LE::. . ~'. 1.06 -353298 Rel~lace DamagedWoodSheathing and Decking__ ~011AA 1/2" Plywood 667 SF 1.53 102051 Z01.1AB 5/8" Plywood 333 SF 1.63 542i79 Z011AC 3/4" Plywood 3,333 SF 1.75 583275 ~.01 lAD 1 1/2" T&G Joint Plank & Paint (exterior) V 17 LF 7.79 13243 ~011AE 1 1/2" T&G Joint Plank & Stain (interior) V 17 LF 7.79l 132243 ~OIIAF "WoodNailer - 6" & up NomWidth 167 LF 2.92 48764 ~.01 lAG WoodNailer - 4" NomWidth 667 LF 2.22 148074 ~011A_T-I Fascia Wood 111 LF 3.34 3707d ~012 Gutter & Downspouts ~,012AA RemoveDownspout & Cap Gutter 7 EA 5.57 3829S ~.012AB RemoveGutter/Downspout 556 LF 1.11 6171~ ~,012AC Gutter, "K", 5", 26 Ga. 111 LF 3.34 37074 ~012AD PrefmishedGutter, 24 Ga., max30" Stretchout 67 LF 6.68 44756 !012AE Downspout,2x3", 26 Ga. 56 LF 3.34 187.04 ~.012AF Downspout,3x4", 26 Ga. 67 LF 3.74 250.5~ ~.012AG Downspout,Round, Corrugated, 4" 33 LF 128.Y1~ 3.90 Prefinished Downspout,26 Ga., max30" Stretchout 67 LF 3.34 223.~8 Gutter Lining, Brash Applied RubberSealant 167 LF 2.22 370.Y4 ~012AK Gutter Lining, EPDM, rail 60 167 LF 5.57 930.19

~

I

Revised

per

Amendment

0001,

dated

12

March

2001

Case 1:04-cv-00473-MBH

Document 62-3

Filed 04/22/2005

Page 11 of 11

Solicitation Contract

~umber F48608-01-R-0001 Number F48608-01-D-XXXX Page 22 of 58

Gutter Screen Mesh 167 LF 2.22 2012AM Gutter, 1/2 Round,5", 26 Ga. 11 LF 5.5Z WSA Access Delays 2013 2013AA Delays 50 CRH* 96.00i Lightnin._.~g ProtectioIi:~System 2014A.A Remove Integrated System Air Terminals and Conductors 10 EA 500.0( 2014AB Work Ar0uhd Concealed Lighl~ng Protection System, Add 333 SQ 11.13 This Cost to RoofInstallation Cost per SQ 2014AC Restore Integrated System Air Terminals and Conductors 13 EA 500.0~ 2014AD Electrically Test RestoredSystemer22r_.~peci~cations 1 EA 2000.0C 2015 Miscellaneous 2015AA Crane Rental 5 HR 210.00 13 2015AB Factory FormedRubber Flashing Boot (up to 6" Dia) EA ll0.0O Z015AC Replace Vent Rain Hood(to 8" Dia Vent) 3 EA 110.00 Z015AD Replace Vent Rain Hood(to 16" Dia Vent) 3 EA 140.00 Z015AE SteeI plate -3/16" (Over Abandoned Penetrations) 50 SF 10.57 Z015AF Reroute Conduit/Wiring 50 LF 3.34 Z015AG Painting 300 SF 1.11 Z016 LowSlol~e Roof Accessories ~016aa Concrete Paver Blocks, 2' x 2' Square x Approx.2" Deep, 50 EA 4.25 /. Minimum Weight 40 lb. Each Metal Roof Drain Domes 2 EA 55.00 Z016AC Metal RoofDrain Inserts 2 EA 55.00 Z016AD Metal Roof Drain Rings 2 EA 55.00 ~,016AE Metal Roof Drain Bolts 6 EA 11.00 ESTIMATED TOTAL

370.7z 61.2 4,800.0( 5000.0( 3706.2g 6500.0C 2000.0( 1050.0C 1430.0t 330.0G 420.00 528.5C 167.00 333!.0C 2!Z50 110!.00 110;00 110!00 66~00 436,156!95

I

METAL ROOFING REFERENCE SPECIFICATIONS 7530, CLLN# 2017 2017AB 2017AC 2017AD 2017AE 2017.AF 2017AG 20
20. .~

7631 EST. UNIT ESTIMATED AMOUNT 37400 58345 123i21 36963 340i00 660i00 660i00 34000 440

DESCRIPTION Section II Demolition Vapor Barrier Remove Metal Fascia / Flashing RemoveWoodNailers/Curbs RemoveSealant R & R Curb Mount Equip ( YxYMax - Unpowered) R & R Curb Mount Equip ( Yx-Y Max- Powered R & R Curb Mount Equip (over YxY- Powered) Remove& Scrap Abandoned Mechanical Equipment/Vents Remove& Scrap Sewer Vent/Pipe Flashing
Revised per Amendment 0004, dated 28 June 2001

QTY

PRICE 17 .35 1.11 1.11 170.00 220.00 220.00 170.00 2.20

2o17~- RemoveUnderlayment /

22 1,667 111 333 2 3 3 2 2

LF SF LF EA EA EA EA EA