DEPARTMENT OF HEALTH AND HUMAN SERVICES PUBLIC HEALTH SERVICE FOOD AND DRUG ADMINISTRATION
FIELD TEST SERIAL NO. (1-8)
MOBILE RADIOGRAPHIC SYSTEMS FIELD TEST RECORD
(Use Form FDA 2782, Field Test Record Continuation, if more space is needed.)
Print Legibly. Use Black Ball Point Pen. Enter One Character Per Box. Do Not Write in Shaded Area.
MR
REGIONAL REVIEW (NAME)
Card No.
(9-10)
Test Procedure 1. MR 11
Component Certification Information 2. Indicate the status of each as follows:
13
C - Certified N - Not Certified
V - Certified with a Variance X - Not Present
14 17
Beam Limiting Device
15 18
High Voltage Generator Tube Housing Assembly with Beam Limiting Device and High Voltage Generator
16 19
X-ray Controls with High Voltage Generator Other (Specify)
Tube Housing Assembly
X-ray Controls
20
3. Generator Type: F-fullwave; H-halfwave; C-Capacitor;
21
Test Setup MDH (Pulse Exposure) 4.5 mm Al
Technique Factors 4.
kVP
5. over 70 kV
mA
10
6.
22
q
24
sec OR
25
27
pulses
28
7.
q
31
mAs
32
34
35
Beam Quality:
38
Capacitor discharge equipment - use maximum mAs for kV selected.
S6
8.
q
mR
@
4.5 mm Al
39
9.
q
43
mR @ 3.5 mm Al
44
10.
q
48
mR @ 2.5 mm Al
49
11.
q
53
mR @ 1.5 mm Al
54
12. Warning Label Present
58
13. Exposure Terminated After Preset Time Interval Preset mAs, Or Preset Number of Pulses
Y - Yes N - No
59
Y - Yes
N - No
60
Reproducibility (no AI in beam) 14.
q
15.
mR msec
61
16.
q
65
17.
mR
66
69
msec
70
18.
q
74
19.
mR
75
78
msec
11
15
21.
q
16
mR
19
msec
11
20.
20
24
Page 1 of 2 Pages
25
28
Created by: PSC Media Arts (301) 443-2454
FORM FDA 2783 (10/80)
EF
DEPARTMENT OF HEALTH AND HUMAN SERVICES PUBLIC HEALTH SERVICE FOOD AND DRUG ADMINISTRATION
FIELD TEST SERIAL NO. (1-8)
MOBILE RADIOGRAPHIC SYSTEMS FIELD TEST RECORD
(Use Form FDA 2782, Field Test Record Continuation, if more space is needed.)
Reproducibility (Continued) 22.
q
Print Legibly. Use Black Ball Point Pen. Enter One Character Per Box. Do Not Write in Shaded Area.
MR
REGIONAL REVIEW (NAME)
23.
mR
29
24.
q
33
mR
38
26.
q
42
mR
Data here if any of items 14, 16, 18 and 20 differ by more than 10 percent of the largest value.
msec
34
25.
37
msec
43
27.
46
msec
47
28.
q
51
29.
mR
52
55
msec
56
30.
q
60
31.
mR
61
64
mRm
65
32.
q
69
33.
mR
70
73
msec
11
Linearity 34.
mA
15
16
Illuminance (uncorrected; SID = 42.5" (106cm)) 39.
total ambient
19
=
q
20 22 If change in mA causes a kVp shift, readjust kVp (if possible) to value selected at item 4 above.
35.
q
fc
23
25
q
40.
total ambient
=
fc
26
28
q
41.
mR
=
fc total ambient
29
33
42.
q
34
36
q
12
36.
mR
=
fc total ambient
37
37.
q
41
mR
42
44
45
38.
q
49
mR
X-Ray Field/Light Field Alignment: 43. Length Misalignment
q
50
54
44.
cm
55
Width Misalignment
q
56
cm
57
Minimum Source To Skin Distance 45. Outside Separation of Image of Focal Spot Strips
q
58
cm
59
Standby Radiation: (Capacitor discharge equipment only) 46.
q
61
47.
mR min sec
62 REMARKS
66
67
68
69
CHECK IF CONTINUATION SHEET USED
FORM FDA 2783 (10/80)
Page 2 of 2 Pages