DEPARTMENT OF HEALTH AND HUMAN SERVICES PUBLIC HEALTH SERVICE FOOD AND DRUG ADMINISTRATION
FIELD TEST SERIAL NO. (1-8) Print Legibly. Use Black Ball Point Pen. Enter One Character Per Box. Do Not Write in Shaded Area.
AR
REGIONAL REVIEW (NAME)
ABOVETABLE X-RAY SOURCE RADIOGRAPHIC SYSTEMS FIELD TEST RECORD
(Use Form FDA 2782, Field Test Record Continuation, if more space is needed.)
Card No.
(9-10)
Test Procedure 1.
Beam Limiting Device Information 2. Manufacturer
Mfr. Code
AR
11 13
3.
14
Unique ID
17
Model No. Serial No.
18
Date of MFR Mo/Yr
23
24
36
37
40
X-Ray Table Information: 4. Manufacturer
Mfr. Code
41
Unique ID
44
10
5. Model No. Serial No.
45
Date of MFR Mo/Yr
50
51
67
68
71
Component Certification Information 6. Indicate the status of each as follows: C - Certified N - Not certified Beam Limiting Device V - Certified with a Variance X - Not Present Table Film Changer
72
73
74
75
Tube Housing Assembly
76
Cradle
77
Other (Specify in Remarks)
78
X-ray Controls
79
High Voltage Generator
Initial Setup: 7. Means To Indicate When Beam Axis Is Perpendicular to Image Receptor Plane Means To Center Diagnostic Source Assembly Over Image Receptor Y--YES N--NO
11
8.
9.
12
Indicated Source To image Distance (SID) Technique Factors
q
Y--YES N--NO OR cm
13
15
inches
q
16
19
S6
11
14. MDH (Pulse Exposure) 4.5mm Al MDH Threshold Setting, 0.5-3 phase, 0.2-1 phase
10.
20
11.
22
kVp
over 70 kV 12.
23
13.
26
mA
q
27
30
sec
ΓΈ
q
31
32
34
mAs
FORM FDA 2784 (10/80)
Page 1 of 3 pages
Created by: PSC Media Arts Branch (301) 443-2454
EF
DEPARTMENT OF HEALTH AND HUMAN SERVICES PUBLIC HEALTH SERVICE FOOD AND DRUG ADMINISTRATION
FIELD TEST SERIAL NO. (1-8) Print Legibly. Use Black Ball Point Pen. Enter One Character Per Box. Do Not Write in Shaded Area.
AR
REGIONAL REVIEW (NAME)
ABOVETABLE X-RAY SOURCE RADIOGRAPHIC SYSTEMS FIELD TEST RECORD
(Use Form FDA 2782, Field Test Record Continuation, if more space is needed.)
Beam Quality 18.
q
15.
35
39
q
mR @ 4.5mm Al 16.
Technique Factors Indicated Before Exposure
40
Y--YES N--NO
11
19.
41
20.
q
45
mR @ 3.5mm Al
If Multiple Tubes Controlled By Single Exposure Switch, Then Indication Of Tube Selection Both At Control Panel And At Selected Tube Y--YES N--NO X--N/A
46
21.
q
50
mR @ 2.5mm Al 17.
51
Warning Label Present
52 22.
56
mR @ 1.5mm Al
57
Y--YES N--NO Y--YES N--NO
Exposure Terminated After Preset Time Interval, Preset mAs, Or Preset Number of Pulses
58
Reproducibility (no Al in beam) 23.
q
24.
33.
34.
q
11
25.
q
15
mR 26.
16
18
msec 35.
19
q
23
mR 36.
24
26
msec
12
27
27.
q
31
mR 28.
32
34
msec 37.
35
q
39
mR 38.
40
42
msec
43
29.
q
47
mR 30.
48
50
msec 39.
51
q
55
mR 40.
56
58
msec
59
31.
q
63 15
mR 32.
64 16
66 18
msec 41. msec
67
q
71 23
mR 42.
72 24
74 26
msec
11
Linearity 43. mA
mR
19
mR
msec
SID Determination 48. Distance from tabletop to focal spot 49.
q
13
27 30 If change in mA causes a kVp shift, readjust kVp (if possible) to value selected at Item 10 above.
31
q
34
cm
cm
Distance from UTIR to Base of Test Stand (Y)
35
37
44.
q
38
45.
q
42
mR
PBL X-Ray Field/UTIR Size Comparison 50. Film Dimension Along Table Film Dimension Across Table Indicated SID inches OR cm
q
q
43
46.
q
47
mR 51. mR 52. mR
48
q
50
51
q
53
59
q
61
inches
inches
OR
62
q
64
cm
54
47.
q
58
70
72
OR
73
76
cm
65
53. 54.
69
Type of Positive Beam Limitation (PBL)
A. Automatically Adjusts X-ray Field B. Prevents Production of X rays Until Manual Adjustments are Made C. Not Present (Explain in Remarks)
11
A, B, or C
Is the PBL Currently Operating in Conformance with its Design 55. Light Field Along Table 56.
q
12
Light Field Across Table
Y--YES
N--NO
14
13
57. Indicated SID
15
q
cm
q
16
inches 59. OR Light Field Across Table
q
18
cm
cm
19
58. Light Field Along Table
q
21
cm
22
25
q
26
28
29
31
cm
FORM FDA 2784 (10/80)
Page 2 of 3 pages
DEPARTMENT OF HEALTH AND HUMAN SERVICES PUBLIC HEALTH SERVICE FOOD AND DRUG ADMINISTRATION
FIELD TEST SERIAL NO. (1-8) Print Legibly. Use Black Ball Point Pen. Enter One Character Per Box. Do Not Write in Shaded Area.
AR
REGIONAL REVIEW (NAME)
ABOVETABLE X-RAY SOURCE RADIOGRAPHIC SYSTEMS FIELD TEST RECORD
(Use Form FDA 2782, Field Test Record Continuation, if more space is needed.)
PBL Sizing (Continued) 60. Film Dimension Along Table 61. Film Dimension Across Table 62. Indicated SID 63. Light Field Along Table
q q q
32
34
inches
OR
q
35
q
38
cm
39
inches
41
inches
OR
42
q
45
cm
q
cm
46
q
48
OR 64.
49
52 56
14
65.
53
q
55
cm
Light Field Across Table
58
cm
Indicated SID 66. Light Field Along Table
59
q
61
inches 67.
OR
q
62
65
cm
66
68
inches
Light Field Across Table
q
69
71
cm
PBL Operation: 68. In PBL Mode, Adjustment Possible To Field Size Smaller Than Image Receptor 69. Y--YES N--NO Automatic Return To PBL When Image Receptor Is Changed Y--YES N--NO N--NO
72
73
Y--YES
70. X-ray Production Prevented At SID's Where Operation Is Not Intended
74
Actual Versus Indicated Field Size 71. Beam Limiting Device Numerically Indicates Field Size 72. Y--YES N--NO Indicated SID inches OR cm
q
q
11
12
q
14
15
q
18
cm
73. Film Dimension Along Table 74. Film Dimension Across Table 75. Light Field Along Table
q
19 25
76.
q
21 27
inches
OR
22
q
24 30
q
inches
OR
28
cm
31
33
cm
Light Field Across Table
34
36
cm
Illuminance (uncorrected; SID = 42.5" (106 cm)) 77. 78.
=
total ambient
q
37
q
39
fc
total ambient
=
80.
q
40
q
42
fc
15
79.
=
total ambient
fc
=
total ambient
fc
43
45
46
48
X-Ray Field/Light Field Alignment and Size Comparison 81. 83. Light Field Along Table 85. Misalignment Along Table X-Ray Field Along Table 82.
q
cm
X-Ray Field Across Table
q
cm
49
q
51
cm
84. Light Field Across Table 86. cm Misalignment Across Table
52
q
54
cm
55
q
57
58
q
60
cm
61
X-Ray Field/UTIR Centers Comparison 87. Centers Misalignment
62
63
64
q
cm
65
Page 3 of 3 pages
66
FORM FDA 2784 (10/80)